DIN17660 CuZn20Al2 F39 Seamless Copper Alloy Tube For Heat Exchanger

产品详情
原产地:中国中国
品牌名称: TONG CHUANG品牌名称: TONG CHUANG
认证:ABS、BV、DNV-GL、PED、TUV、LR、KR、NK、CCS
Model Number: DIN17660 CuZn20Al2 F39
付款和发货条款
最低订购量:1000 公斤
价格面议
包装细节木箱/铁箱/带塑料盖的捆包
交货时间:视数量而定
付款条件:T/T, L/C
供应能力:每月 1000 吨

SKU: 1701 分类:
规格DIN17660年级CuZn20Al2
表面:抛光测试:ET, HT
完成:冷拔申请:Air Condition Or Refrigerator,Water Tube,water Pipe,Oil Cooler Pipe,Water Heater
强光

F39 SMLS Copper Alloy Tube

CuZn20Al2 Copper Alloy Tube

Condenser Copper Round Tube

DIN17660 CuZn20Al2 F39 Seamless Copper Alloy Tube For Heat Exchanger

TONG CHUANG is one of the biggest copper alloy tubes manufacturer, supplier and exporter in China. We are supplying copper alloy tubes to various industries around the world.

 

Our copper alloy tube is widely used in the surface of condenser, heat exchanger, and evaporators. They offer high strength, excellent corrosion resistance, and good creep resistance at elevated temperatures.

 

We are glad to supply your needs whatever the sizes, shapes, dimensions you want for copper alloy tubes. TONG CHUANG will help you with all your tubes necessities. Contact one of our experts today to find out how we can meet your tubing needs.

DIN17660 CuZn20Al2 F39 Chemical Composition

化学成分
要素成分, %
铜,包括银76.0-79.0
Sn-
Al1.8-2.5
镍,包括钴-
Pb0.07 最大值
0.06 最大值
平衡
0.02-0.06

等效材料

材料名称相应材料符号
GB/T8890ASTM B111BS2871JIS H3300DIN1785 标准
铝 黄铜HAL77-2C68700CZ110C6870CuZn20Al2

包装

拉伸要求

等级温度名称拉伸强度屈服强度
标准Min. ksiMin. ksi
CuZn20Al2O61退火5018

DIN17660 CuZn20Al2 F39 Mechanical Properties

等级温度名称退火温度, °C拉伸强度,最小值屈服强度,最小值HV
 代码名称ksiMpaksiMpa
CuZn20Al2O61退火高于 6505034518125150
Nondestructive Testing
Each tube shall be subjected to the eddy-current test in Eddy-Current Test.
Tubes may be tested in the final drawn, annealed, or heat-treated temper or in the drawn temper before the final anneal or heat treatment unless otherwise agreed upon by the supplier and the purchaser. The purchaser may specify either of the tests in Hydrostatic Test or Pneumatic Test as an alternative to the eddy-current test.

Eddy-Current Test—Each tube shall be passed through an eddy-current testing unit adjusted to provide information on the suitability of the tube for the intended application. Testing shall follow the procedures of Practice E243.

Hydrostatic Test—Each tube shall stand, without showing evidence of leakage, an internal hydrostatic pressure sufficient to subject the material to a fiber stress of 7000 psi [48 MPa] as determined by the following equation for thin hollow cylinders under tension. The tube need not be tested at a hydrostatic pressure of over 1000 psi [7.0 MPa] unless so specified.

P = hydrostatic pressure, psig [MPa];
t = thickness of tube wall, in. [mm];
D = outside diameter of the tube, in. [mm]; and
S = allowable stress of the material, psi [MPa].

应用

-Heat exchanger and evaporators
-Distiller tubing
-Condenser

-Gland Steam Condensers

-Steam Ejector

-Turbine Oil Coolers