Specification: | DIN17660 | Grade: | CuZn20Al2 |
---|---|---|---|
Surface: | Polished | Test: | ET, HT |
Finish: | Cold Drawn | Application: | Air Condition Or Refrigerator,Water Tube,water Pipe,Oil Cooler Pipe,Water Heater |
High Light: | F39 SMLS Copper Alloy Tube, CuZn20Al2 Copper Alloy Tube, Condenser Copper Round Tube |
DIN17660 CuZn20Al2 F39 Seamless Copper Alloy Tube For Heat Exchanger
TONG CHUANG is one of the biggest copper alloy tubes manufacturer, supplier and exporter in China. We are supplying copper alloy tubes to various industries around the world.
Our copper alloy tube is widely used in the surface of condenser, heat exchanger, and evaporators. They offer high strength, excellent corrosion resistance, and good creep resistance at elevated temperatures.
We are glad to supply your needs whatever the sizes, shapes, dimensions you want for copper alloy tubes. TONG CHUANG will help you with all your tubes necessities. Contact one of our experts today to find out how we can meet your tubing needs.
DIN17660 CuZn20Al2 F39 Chemical Composition
Chemical Composition | |
Elements | Composition, % |
Cu, incl. Ag | 76.0-79.0 |
Sn | – |
Al | 1.8-2.5 |
Ni, incl. Co | – |
Pb | 0.07 max |
Fe | 0.06 max |
Zn | Balance |
Mn | 0.02-0.06 |
Equivalent Material
Material Designation | Corresponding Material Symbol | ||||
GB/T8890 | ASTM B111 | BS2871 | JIS H3300 | DIN1785 | |
Aluminums Brass | HAL77-2 | C68700 | CZ110 | C6870 | CuZn20Al2 |
Packing
Tensile Requirements
Grade | Temper Designation | Tensile Strength | Yield Strength | |
Standard | Former | Min. ksi | Min. ksi | |
CuZn20Al2 | O61 | Annealed | 50 | 18 |
DIN17660 CuZn20Al2 F39 Mechanical Properties
Grade | Temper Designation | Annealing temperature, °C | Tensile Strength, min | Yield Strength, min | HV | |||
Code | Name | ksi | Mpa | ksi | Mpa | |||
CuZn20Al2 | O61 | Annealed | above 650 | 50 | 345 | 18 | 125 | 150 |
Tubes may be tested in the final drawn, annealed, or heat-treated temper or in the drawn temper before the final anneal or heat treatment unless otherwise agreed upon by the supplier and the purchaser. The purchaser may specify either of the tests in Hydrostatic Test or Pneumatic Test as an alternative to the eddy-current test.
Eddy-Current Test—Each tube shall be passed through an eddy-current testing unit adjusted to provide information on the suitability of the tube for the intended application. Testing shall follow the procedures of Practice E243.
P = hydrostatic pressure, psig [MPa];
t = thickness of tube wall, in. [mm];
D = outside diameter of the tube, in. [mm]; and
S = allowable stress of the material, psi [MPa].
Applications
-Heat exchanger and evaporators
-Distiller tubing
-Condenser
-Gland Steam Condensers
-Steam Ejector
-Turbine Oil Coolers