Standard: | ASTM A213/ASME SA213 | Material: | T5 |
---|---|---|---|
Type: | Seamless | Technique: | Hot Rolled |
Surface: | Black Painting | Application: | Boiler/Heat Exchanger/Oil&Gas |
High Light: | Hot Rolled Seamless Alloy Steel Tubing, Black Painted Alloy Steel Seamless Tube, T5 Boiler Alloy Steel Seamless Tube |
ASTM A213 Grade T5 Alloy Steel Seamless Tube Black Painted for Boiler
TONG CHUANG GROUP deal with Stainless Steel and tube already more than 33 years, every year sell more than 12000 tons of Stainless Steel and tube. Our client already cover more than 65 countries.
Description
ASTM A213 standard is a common used specification for Seamless Ferritic and Austenitic Alloy-Steel Boiler, Super heater, and Heat-Exchanger Tubes,The material has carbon, manganese, sulfur, silicon, phosphorus, chromium and molybdenum in the composition which makes the material strong, corrosion resistant and ductile. The Sa213 Grade T5 Tubes have similar strength to the 304 and 316 grades of stainless steel. The chromium and molybdenum content of the material makes it chloride resistant and pitting resistant. The A213 T5 Alloy Steel Tube is also resistant to reducing acids and other general corrosive media.
ASTM A213 T5 Tube can be either hot rolled or cold drawn with delivery conditions ranging as normalizing rolled, thermomechanical rolled, normalized and tempered, quenched and tempered and so on.
Equivalent Material
UNS | ASTM | EN | DIN | JIS | GB |
K50400 | P5 | 12Cr9Mo | X12CrMo91 | STBA26 | / |
Chemical Composition
Grades | C | Si | Mn | P | S | Cr | Mo |
T5 | ≤ 0,15 | ≤ 0,50 | 0,30-0,60 | ≤ 0,025 | ≤ 0,025 | 4,0-6,0 | 0,45-0,65 |
Mechanical Properties
Material | Yield strength ReH/Rp0,2 N/mm² min | Tensile strength Rm N/mm² | Elongation A % min |
T5 | 205 | 415 | 20 |
Heat Treatment Requirements of A213 T5 Alloy Steel Seamless Tubes
T5, T9, T11, T22 and T91 | |||
Grade | Heat Treatment Type | Normalizing Temperature Range F [C] | Subcritical Annealing or Tempering Temperature Range F [C] |
T5 (b,c) | Full or Isothermal Anneal | ||
Normalize and Temper | ***** | 1250 [675] | |
Subcritical Anneal (T5c only) | ***** | 1325 – 1375 [715 – 745] | |
T9 | Full or Isothermal Anneal | ||
Normalize and Temper | ***** | 1250 [675] | |
T11 | Full or Isothermal Anneal | ||
Normalize and Temper | ***** | 1200 [650] | |
T22 | Full or Isothermal Anneal | ||
Normalize and Temper | ***** | 1250 [675] | |
T91 | Normalize and Temper | 1900-1975 [1040 – 1080] | 1350-1470 [730 – 800] |
Quench and Temper | 1900-1975 [1040 – 1080] | 1350-1470 [730 – 800] |
Application:
- Off-Shore Oil Drilling Companies
- Condensers
- Heat exchangers
- Power Generation
- Petrochemicals
- Gas Processing
- Specialty Chemicals
- Pharmaceuticals
- Pharmaceutical Equipment
- Chemical Equipment
- Sea Water Equipment
- Pulp and Paper Industry